Pall
ForteBio Logo
Instruments
Dip and Read™ Biosensors
Aminopropylsilane (APS)
Amine Reactive 2nd-Generation (AR2G)
Anti-GST (GST)
Anti-hIgG Fc Capture (AHC)
Anti-mIgG Fc Capture (AMC)
Anti-human IgG Fc
Anti-murine IgG Fv
Anti-Penta-HIS (HIS)
Ni-NTA (NTA)
Protein A
Protein G
Protein L
Streptavidin (SA)
Super Streptavidin (SSA)
Custom Biosensors
Dip and Read™ Assay Kits
Octet Software
Custom Services
Accessories
BlItz™ System

Dip and Read™ Amine Reactive Second-Generation (AR2G) Biosensors
EDC/Sulfo-NHS Based Immobilization for Kinetic Characterization of
Primary Amine Containing Biomolecules

The AR2G biosensor is a newly engineered biocompatible surface matrix that delivers enhanced performance for kinetic assays compared to the original Amine Reactive (AR) biosensor for most proteins (Figure 1). AR2G routinely achieves greater signal intensity than the AR biosensor during both the loading (immobilization of ligand) and association (detection of analyte) steps of an assay while delivering the same reliable kinetic values. Evaluation of four antibody proteins demonstrated an increase in the intensity of the loading signal by an average of 4-fold with one example extending to 7.5-fold (Figure 1). A screen of several buffer systems determined that the AR2G chemistry is highly compatible with acetate buffer, which is both commonly available and cost-effective. A decrease in non-specific binding events to the AR2G surface compared to AR has also been demonstrated.

Learn more: download Amine Reactive Second-Generation (AR2G) Biosensor Datasheet

Key Features

  • Rapid immobilization of proteins and peptides
  • Kinetic analysis of ligand-analyte pairs
  • Rapid assay development
  • Second-generation amine reactive detection surface (AR2G)
Performance comparison of AR2G and AR biosensors

Figure 1: Performance comparison of AR2G and AR biosensors. Four proteins (20 mg/mL)were immobilized on AR2G biosensors using EDC/S-NHS (acetate buffer at pH 4, 5 and 6) and on AR biosensors using EDC-NHS (MES buffer at pH 4, 5 and 6). The signal intensity achieved with the AR2G biosensors during loading was significantly greater than that with the AR biosensors for all proteins. The average increase was approximately four-fold with a maximum increase of 7.5-fold (anti-rabbit IgG). The enhanced performance of the AR2G biosensor was robust towards pH with increased loading density overserved at all pH values.

For More Information

Visit our literature page to download technical notes, application notes, posters and customer presentations.

^ TOP